Locat properties (Interface: Locat)
 
The available properties for this interface are:
 
Name Get Set Type English description Dutch description French description
pBrowseVisible VARIANT_BOOL Visible in search list Zichtbaar in zoeklijst Visible dans liste de recherche
pCardUse BYTE Status Status Etat
pCircuitCode BSTR Circuit code Circuitcode Code de circuit
pCode BSTR Code Code Code
pCreDate DATE (date) Addition: date Toevoeging: datum Addition: date
pCreTime DATE (time) Addition: time Toevoeging: tijdstip Addition: temps
pCreUsr BSTR Addition: by Toevoeging: door Addition: par
pDescription BSTR Description Omschrijving Description
pInfo BSTR Information Informatie Information
pSysNum LONG System number Systeemnummer Numéro de système
pText1 BSTR Text field 1 Tekstveld 1 Champ de texte 1
pText2 BSTR Text field 2 Tekstveld 2 Champ de texte 2
pText3 BSTR Text field 3 Tekstveld 3 Champ de texte 3
pText4 BSTR Text field 4 Tekstveld 4 Champ de texte 4
pUpdDate DATE (date) Modification: date Wijziging: datum Modification: date
pUpdTime DATE (time) Modification: time Wijziging: tijdstip Modification: temps
pUpdUsr BSTR Modification: by Wijziging: door Modification: par
pValue1 DOUBLE Numerical field 1 Numeriek veld 1 Champ numérique 1
pValue2 DOUBLE Numerical field 2 Numeriek veld 2 Champ numérique 2
pValue3 DOUBLE Numerical field 3 Numeriek veld 3 Champ numérique 3
pValue4 DOUBLE Numerical field 4 Numeriek veld 4 Champ numérique 4
pWarehouse BSTR Warehouse Magazijn Magasin
             
vArticleList BSTR Articles on this location Artikels op deze locatie Articles sur cet emplacement
vCardUseDsc BSTR Status descr. Status omschr. Etat descr.
 
Remarks
Properties starting with the character 'p' are the 'real', physical fields of this interface, the ones starting with 'v' are 'virtual' fields. The value of p-fields is written to disk, while the value of v-fields is calculated at run time.
The get accessor of these properties returns a VARIANT.
The set accessor of these properties needs a VARIANT as input.
More detailed information on these properties (type, length,...) can be found in the 'ODBC File Description'-module of your Venice installation. See file 'LOC - Location (Locat.btr)'.
The property names that are underlined represent BYTE fields that can have several values. Click on the link to see more information on the possible choices.
Calculation fields are added dynamically and cannot be used as properties. They should be used as described in 'How to use calculation fields?'.
You should consult the module parameters to get the necessary info on these calculation fields.